Two-yearly rental electrical safety check
The Victorian two-yearly rental electrical safety check: AS/NZS 3019 assessment, safety switch rules since 2023, the report you keep and repair costs.
Every Victorian rental property needs an electrical safety check of all electrical installations, fixtures and fittings at least every two years, done by a licensed or registered electrician. The check follows the periodic assessment method in AS/NZS 3019 and ends with a written report. Independent electricians who take enquiries from this site quote and do the check themselves.

What the electrician actually checks
The check is a visual inspection plus testing. Expect the electrician to open the switchboard, test each safety switch, check circuit protection, and work through power points, light fittings, fixed appliances and visible cabling. One Melbourne compliance firm describes its check as a visual inspection with specific limited testing, a physical check of the switchboard, testing of each RCD and earth testing.
The regulations do not ask the electrician to rewire the house or bring it up to the standard a new home would meet. They ask for a periodic assessment of the installation as it is, with defects and recommendations written up.
The safety switch and circuit breaker rule
Since 29 March 2023 the rental minimum standards require all power outlets and lighting circuits to be connected to a switchboard-type circuit breaker that complies with AS/NZS 3000, and to a switchboard-type residual current device (a safety switch). Older homes with ceramic rewireable fuses or a board with only one or two RCDs often fail here. The fix is usually extra safety switches or a new switchboard, and that is a separate quote from the check itself.
Who can do it?
Consumer Affairs Victoria says the electrician should be licensed with Energy Safe Victoria and working as or for a Registered Electrical Contractor (REC). In Victoria an electrician must work for an REC to carry out work for a customer. Search the Energy Safe Victoria public registers for the REC number and the electrician’s licence before the visit.
Warning signs between checks
- A safety switch that trips again and again, or one that never trips when tested.
- Warm or discoloured power points and switch plates.
- Flickering lights on one circuit.
- A burning smell near the switchboard.
- Extension leads run under carpet because the renter is short of outlets.
Any of these is a repair job, not something to leave until the next two-yearly visit.
Options compared
| Approach | Includes | Good for |
|---|---|---|
| Electrical check only | Assessment and report, minor items such as a faulty power point sometimes fixed on the spot | Properties with no gas |
| Electrical plus smoke alarms | Two-yearly electrical check and the annual smoke alarm check in one trip | Apartments and all-electric houses |
| Electrical, gas and smoke alarms | All rental safety checks in a single booking | Houses with gas heating or hot water |
| Switchboard upgrade after a failed check | New board, circuit breakers and safety switches, then a Certificate of Electrical Safety | Older wiring that fails the RCD standard |
If the property has gas, the combined compliance visit avoids two separate access arrangements with the renter.
What the electrician needs from you
- Access to the switchboard and meter box, including keys for apartment meter cupboards.
- The renter’s contact details and confirmation that entry notice has been given.
- The last electrical safety report, if you have one.
- Notes on any recent electrical work and the Certificate of Electrical Safety that came with it.
- A list of appliances you supply with the rental, such as an oven, dishwasher or split system.
What you should receive
The record should show the electrician’s name and licence or registration number, the date, the results including repairs needed and actions taken, and a report prepared under AS/NZS 3019. You keep the most recent record until the next check replaces it, and a renter can ask for a copy in writing. Before a new agreement is signed, the incoming renter must be told the date of the last electrical check and any recommendations still open. The details are on the Consumer Affairs Victoria page for rental providers.
If the electrician carries out repairs, they must also give you a Certificate of Electrical Safety (COES) for that work. Replacing the main switchboard is prescribed work: an independent Licensed Electrical Inspector has to inspect it, and it cannot be switched on until that inspection is done. Energy Safe Victoria explains this on its page about certificates for the community.
What it costs
One Melbourne compliance business publishes $330 plus GST for an electrical safety test on its own, and $400 plus GST with a smoke alarm test added. Repairs found during the check are where the real spread is. A Melbourne cost guide lists safety switch installation at $160 to $370 per switch and a switchboard upgrade at $945 to $2,950, both including GST. The cost guide for Melbourne rental safety checks compares these with plan pricing.
What a careful electrician will not do
- Sign off a property where they could not get to the switchboard or into part of the house.
- Leave a dangerous defect in place without isolating it and telling you in writing.
- Issue a report with no test results, or a pass that only says “visual OK”.
- Do switchboard work without a COES, or energise prescribed work before it is inspected.
Local angle
Melbourne’s rental stock runs from 1880s terraces in the inner north to post-war and newer houses in growth areas such as Werribee. In older stock, years of extensions and part rewires are common, so test results vary from room to room. Inner-city apartment towers bring a different problem: the unit’s own board may be inside the apartment while the main switchboard sits in a locked services room run by the owners corporation. Read the Melbourne CBD and city area page for the apartment side and the Brunswick page for older terraces.
Next step
Find the last report and confirm switchboard access, then request an electrical safety check with the suburb and property type. If gas appliances are present, the gas safety check is due on the same two-yearly cycle.
Frequently asked questions
- Will the electrician upgrade my switchboard during the check?
Not as part of the check itself. The check assesses and reports. If the board does not give every outlet and lighting circuit safety switch protection, the electrician will quote the upgrade separately for your approval.
- Is a Certificate of Electrical Safety issued for the check?
A certificate records electrical installation work. If the electrician only inspects and tests, the record is the safety check report. If they replace or install anything, they must give you a certificate for that work.
- Does the electrician test appliances the renter owns?
The check covers the electrical installation and the fixtures and fittings that come with the rental. Some providers also look over appliances the owner supplies, such as an oven or dishwasher. Renters' own appliances are their responsibility.
- What standard does the electrical check follow?
The assessment follows AS/NZS 3019, the Australian and New Zealand standard for periodic assessment of electrical installations, and the report is prepared under that standard.
- How do I check the electrician is properly licensed?
Ask for their licence number and their Registered Electrical Contractor number, then search both on the Energy Safe Victoria public registers before the visit.